Product Description
Low Dose Mobile C-arm X-ray Machine FN-ALC-200
Specifications
Configuration
NO |
Brand |
Model |
Product Name |
Quantity |
1 |
Foinoe |
Foinoe -C-12L |
X-ray digital flat panel detector |
1 |
2 |
Foinoe |
TSC-2 |
Image processing system |
1 |
3 |
JPI |
JPI Grid-1000 |
X-ray grid |
1 |
4 |
Foinoe |
FSQ-C-1 |
High Frequency Generator |
1 |
5 |
Foinoe |
CQG-1 |
X-ray tube |
1 |
6 |
Foinoe |
CXS-1 |
Collimator |
1 |
7 |
Foinoe |
ALC-1 |
Mechanical body |
1 |
8 |
Foinoe |
AYC-1 |
Mobile console |
1 |
9 |
Foinoe |
HRF-M52 |
Foot switch |
1 |
10 |
Foinoe |
DXRay Diagnost-XC |
Software |
1 |
Flat Panel Detector
Specifications
Detector type: a-Si EPID (amorphous silicon imaging device)
Scintillator material: CsI (Cesium iodide)
Images Size: 9"x9"
Maximum pixel matrix: 1024*1024
Minimum pixel spacing: 200μm
Radiography spatial resolution: ≥2.5l p/mm, 16bits
Fluoroscopy spatial resolution: ≥1.8l p/mm
Maximum frame rate of pulse fluoroscopy: 15fp/s
Fluoroscopy image stabilization time: ≤2S
Imaging time:
Radiography mode: ≤1.5s
Pulse fluoroscopy mode: ≤0.5s
Continuousfluoroscopy mode: ≤0.5s
Intelligent dose control (IDC) function
High Frequency Generator
Input power supply voltage: single phase AC, 220 V (± 10%)
Input power frequency: 50 Hz / 60 Hz
Output power: 5KW
Tube voltage range: 40kV ~ 120kv
Tube current:
Radiography mode: 1mA ~ 100mA
Pulse fluoroscopy mode: 0.5mA ~ 13mA
Continuous fluoroscopy mode: 0.5mA ~ 6mA
Automatic brightness control (ABS) function.
X-ray tube
Tube voltage: 130kv
Tube power: 5kW / 17kw
Focus size: 0.3mm/0.6mm
Anode target angle: 10 °
Maximum anode heat capacity: 150kJ (200kHU)
Heat capacity of X-ray tube: 1000kJ (1333.34kKU)
Collimator
Control mode: Electric
Square range: 210mm*210mm at SID 1000mm
(It has the function of one key in positioning, and the field of view is adjustable)
Mechanical control system
Orbital movement: ≥ 130 °
Revolution around Horizontal Axis: ±195 °
Ascending & Descend: 0mm ~ 400mm
Forward and Backward Movement: 0 mm ~ 200 mm
Revolution around Vertical Axis: ±15 °
C-arm opening: 800mm
C-arm arc depth: 640mm
Focus screen distance (SID): 1000mm
Mobile console
Input voltage: AC 220 V
Input power frequency: 50 Hz / 60 Hz
X-ray grid
Focus: 100cm
Grid ratio: 10: 1
Size: 240mm * 240mm
Foot switch
Structure: single row, 2-connected, wired
Mode: Fluoroscopy mode, radiography mode
Protection level: IP68
Image Processing System
Software: DXRay Diagnost-XC
Patient management: Manual registration and worklist automatic query registration.
Patient data modification function: A temporary patient can be set by physician and the data of the temporary patient can be modified.
Apparatus programmed radiography (APR): After selecting the position on the software, the software displays the recommended exposure parameters.
Image acquisition: Static image acquisition, dynamic image acquisition, video storage, video playback, image automatic window adjustment, image manual window adjustment, video manual window adjustment.
Image processing: Image correction, image reversal.
Image observation: View static image, view dynamic image, video frame extraction, image data measurement, window width and window level adjustment, image flip, image rotation, image scaling, image restoration.
Local magnification of fluoroscopy image: It can be magnified in three levels, 1.5 times, 2 times and 3 times respectively.
Secondary screen locking function: In video acquisition or playback, the user can select a frame from the video image and lock it on the sub screen as a referenceimage for operation.
Ball tube indication function: The software has the function of real-time indicating the heat capacity of the ball tube.
Dose statistics: Dose statistics and DAP display during the acquisition process; Dose statistical analysis report.
Medical record report: Automatic loading of patient information and expert template.
Film printing: Support DICOM3.0 standard laser camera printing.
DICOM transmission: Single image can be sent to any PACS and workstation following DICOM3.0 standard.
Parameter adjustment of beam limiter: The opening size of X and Y blades of the beam
limiter can be controlled in the software interface to adjust the radiation field.
X-ray protection function: X-ray protection can be controlled by software.
Minimum configuration requirements of machine with screen:
Display size: 19 inches
Type: Color, 16.7M
Resolution: 1280 * 1024
Minimum configuration requirements of mobile console display:
Screen size: 27 inches
Type: color, 1.07 billion
Resolution: 2560 * 1440
Detailed Photos
Company Profile
Customer Photo
Send your message to us and click "Send" now