Product Description
Digital Medical X-ray Mammography System Foinoe Mammography Machine X ray Machine DM-200MA-1
Specifications
Configuration
No. |
Brand |
Model |
Product Name |
Quantity |
1 |
Foinoe |
FSQ -DM-1 |
High Frequency Generator |
1 |
2 |
I.A.E. SpA |
XM15 |
X -ray Tube |
1 |
3 |
Foinoe |
XSQM-1 |
Collimator |
1 |
4 |
|
YPZZ-1 |
Compression device 1) Standard compressor: 24cm * 31cm 2) Point pressure compressor: 9cm * 9cm |
1 |
5 |
Foinoe |
ADM-2430M |
X -ray Imaging System |
1 |
6 |
Foinoe |
TSM-1 |
Image Processing System |
1 |
7 |
Foinoe |
DM166-1 |
C -Arm Stand |
1 |
8 |
Foinoe |
MKZT -1 |
Console |
1 |
9 |
LINAK |
/ |
Foot Switch |
2 |
10 |
Foinoe |
EWDW -1 |
2D Positioning Device |
Optional |
11 |
Foinoe |
DWZY-1 |
Position seat |
Optional |
12 |
|
FDZZ-1 |
Amplification device 1.8x magnification |
Optional |
|
|
|
|
|
|
|
|
|
|
High Frequency Generator FSQ -DM-1
• Tube voltage range: 20kV -40kV
• Current time product range: 10 -630mAs
• Current regulation range: 10 -200mA
• Maximum output power: 5.1kW
• Nominal electric power: 4.8kW
• Input power supply voltage: 90 -264VAC, single phase
• Input power frequency: 50Hz / 60Hz
• High voltage transformer structure: non power frequency
X-Ray Tube XM15
• Nominal tube voltage: 40kV;
• Focus: 0.1mm/0.3 mm;
• Target angle: 15°
• Maximum anode heat capacity: 225kJ (300kHU)
• Maximum heat capacity of tube assembly: 320kJ (427kHU)
• Target surface: Mo target
Collimator XSQM-1
• Inherent filtration: 0
• Electric control, with automatic window adjustment function
• The lamp can be turned on electrically or manually
Compression Device YPZZ -1
Compression Device YPZZ -1
• Pressure range: 0-196N; Adjustable
• Maximum stroke range of compressor: 280mm
• Effective size of large compressor: 24cm * 31cm
• Effective size of point pressure compressor: 9cm * 9cm
X-ray Imaging System ADM-2430M
• Scintillator material: Cesium Iodide
• Photodiode: TFT / PD
• Pixel size: 77 microns
• Imaging area: 237mm * 314mm
• Acquisition matrix: 4096 * 3072
• Spatial resolution: 6.0 lp/mm
• With automatic exposure control (AEC)
• DQE 60% @11 p/mm
C-Arm Stand DM166 -1
• C -arm frame rotation, electric control, isocenter rotation
• C -arm rotation range: - 180 ° - +180 °
• When the C -arm assembly is at 0 °, the up and down movement distance from the upper surface of the detector to the frame base: 840mm
• Up and down movement distance from X -ray tube assembly focus to frame base: 840mm
• Rotation range of X -ray tube assembly with swing arm assembly: - 60 ° ~ + 60 °
• The range from the focus of the X-ray tube assembly to the image receiving surface (FID) is 650mm
• It has the function of one key in place
• It has the function of positioning and mirroring
• There are two micro displays on the upper part of the frame to show the compression thickness
Console MKZT -1
• Size: 945mm*515mm*1085mm
Image Processing System TSM-1
• Software name: DXRayDiagnost -MammoFPD
• Software release version: EN V1.0.0
• An acquisition workstation computer and a 24-inch display
• A film viewing workstation computer and a 3D medical display
Software function
• Manage patient information or the information attached to the examination and the image data collected;
• Collect exposure image information;
• Realize image browsing and retrieval;
• It can measure the distance, angle, and area of the region of interest in the image, and can identify it;
• Image post-processing: black and white inversion, rotation and flipping, zoom in and zoom out, local clipping, enhancement, copy, delete, etc.;
• Compatible with DICOM3.0 standard, it can realize image data transmission, print or burn to CD/DVD;
• The system automatically diagnoses faults, and displays corresponding warning messages when a fault occurs;
• Can write and print graphic reports;
• Image typeset and print on paper can be realized;
• Realize database backup and database recovery;
• Support dual -screen image observation;
• Support local window adjustment to enhance local image contrast;
• Can support measurement and annotation;
• Supports automatic alignment of viewing films;
• Supports optional implants: water, saline, unknown, silicone;
• New projection positions can be inserted or added;
• Multiple different inspection procedures such as screening, diagnosis, unilateral photography, galactography, etc. can be preset.
Foot Switch