Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional

Nanjing Foinoe Co., Ltd.
  • Audited Supplier
  • 19 yrs

Contact Supplier

Product Highlights

  • Leaking & Blocking Test: Automatic tests for leaks and blockages before liquid contact, ensuring safety and terminating operation if issues arise.
  • 15-Minute Rapid Cycle: Completes wash-disinfection within 15 minutes, significantly improving endoscope turnover efficiency in clinical settings.
  • Dual Drying Options: Offers both air drying and alcohol drying functions to ensure thorough drying of inner and outer endoscope surfaces.
  • Auto Door & Enclosure: Features an automatic foot-switch door and totally enclosed tank to protect medical workers from sanitizer odors.
  • Process Traceability: Prints all process data for filing and optionally connects to computer systems for synchronized patient and disinfection management.
  • OEM/ODM Support: Provides flexible customization options including samples, designs, and minor adjustments to meet specific client needs.
  • Compliance & Safety: Certified CE and ISO13485, designed per ISO 15883-4 standard with auto-sampling for disinfectant concentration monitoring.

Product Images of Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional

Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional
Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional pictures & photos
Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional
Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional pictures & photos
Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional
Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional pictures & photos
Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional
Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional pictures & photos
Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional
Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional pictures & photos
Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional
Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional pictures & photos
Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional
  • Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional
  • Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional
    Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional
  • Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional
    Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional
  • Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional
    Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional
  • Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional
    Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional
  • Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional
    Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional
  • Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional
    Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional

Find Similar Products

Product Description

Product Description

Automatic Flexible Endoscope Washer-disinfector

Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional
Endoscope Washer-Disinfector

1 General information
Foinoe automatic endoscope washer-disinfector is researched and developed according to standard ISO 15883-4. It adopts automatic micro processor controlling. The product is made of washing tank and pipeline system and can be used with many kinds of disinfectant such as: glutaraldehyde, peracetic acid, OPA, chlorine dioxide and electrolyzed oxidizing water. The treatment for endoscope includes leaking test, blocking test, wash, enzymewash, rinse, disinfection, final rinse, alcohol drying and air drying.
Foinoe series product is applicable for the disinfection of endoscopes such as gastroscope, colonoscopy, duodenoscope and bronchoscope.
Foinoe series includes Foinoe 50 (single-tank) and Foinoe 60 (double-tank). It is also divided into four models of Foinoe 50A, Foinoe 60A, Foinoe 50B and Foinoe 60B based on the type of disinfectant that used in the product. Foinoe 50A and Foinoe 60A are applicable for those one-off disinfectants that should be diluted by water; Foinoe 50B and Foinoe 60B are applicable for those re-usable disinfectants that do not need to be diluted by water.

 
2 Features
  Endoscope protection design
 Leaking test function
The leaking test will finish before the endoscope contacts the liquid and will also keep testing during the operation. The system gives out visual and audible signals and will terminate operation as soon as the leaking value exceeds the setting value.
 Blocking test function (optional)
The blocking test will start before the endoscope contacts the liquid and after the operation. The system gives out visual and audible signals and will terminate operation as soon as the pipe is blocked.

 100% wash-disinfection
 Omnibearing wash-disinfection
The tank equipped with rotating nozzle and spray arm to wash the outer surface of the endoscope, in the meanwhile, the circulating water flow keeps flushing the endoscope from inside.
 Endoscope pressure booster pump
It is used for washing of tiny pipe, such as air/water injection nozzle, to reduce the formation probability of bacteria biofilm.
 Build-in water treatment function
It is equipped with build-in double-level (0.45 μm and 0.2 μm) water filter which could filter out the water impurity to guarantee the disinfection result.    Sterile water rinse
To avoid secondary contamination caused by unsanitary water, the endoscope will be rinsed by sterile water which filtered by 0.2 μm filter after disinfection.
 Drying function
It is used for drying the inner and outer surface of endoscope. Foinoe equipped with air drying and alcohol drying for user to order.

  Self-disinfection function
The self-disinfection program can be started during maintenance or after the termination of operation. The function is designed to disinfect for wash-disinfection tank (includes 0.2 μm filter) and pipeline.

  Most speedy wash and disinfection
An endoscope can be wash-disinfected within 15mins by Foinoe which dramatically improves the endoscope turnover efficiency.
Note: Specific wash-disinfection time depends on the type of disinfectant.

  Perfect medical workers protection
 Auto door with foot switch
The automatic visual glass door is adopted for observing the operation inside the tank. The door can be opened by gently kicking the foot switch.
 Totally enclosed
Foinoe wash-disinfection tank adopts totally-enclosed structure to avoid sanitizer odor leakage so that protect the medical workers.
 Automatic adjuvant injection
Medical workers only need to link the adjuvant container with the tank through a connector to avoid harm that caused from manual adjuvant injection.
 Disinfectant auto-sampling function
Both Foinoe 50B and Foinoe 60B are equipped with the disinfectant auto-sampling function which could monitor the concentration of the disinfectant so that protect user's safety.

  Process traceability system
 Process data printing
For filing purpose, the printer will print all of process data timely during the operation.
 Process data management (optional)
The system collects information of endoscope and operator and connects the process data with computer managing system to achieve synchronization management of patient and disinfection information.

 
  Automatic double-tank disinfector
 Two endoscopes can be treated at same time
Two tanks work independently so that if one of them breaks down will not affect the other one.
 Room-saving
Optimized pipeline system achieves that two tanks share the same water inlet and outlet.
 Cost-saving
Two tanks share the same water filter, air compressor, touch-screen and printer so that save the use-cost.

 
3 Technical parameters
Technical parameters Foinoe 50 Foinoe 60

Foinoe 50A

Foinoe 50B

Foinoe 60A

Foinoe 60B
Overall dim. (LxWxH)cm
74×65×94

74×120×100
Weight (Kg) 100 kg 110kg 200 kg 220kg
Water consumption/cycle
25L

20L

25L

20L
Power supply 220V 50Hz
Power (KW) 4 4.5 8 9
Water supply Water

pressure
(Mpa)
0.2~0.5
Water
hardness
Concentration of calcium carbonate<120mg/L
PH value 6.5~9
Water drainage Dynamic drainage

4 Configurations
No. Item Manufacturer Description
1 Wash-disinfection tank Foinoe It is made of organic glass with glass-fiber which has smooth surface, high strength and long service life.
2 Circulating pump Domestic
brand
It adopts magnetic drive pump which has the advantages of corrosion resistance, low noise,
high stability and free leakage.
3 Control system Foinoe It is equipped with PLC from SIEMENS and touch-screen that have the advantages of excellent accuracy, safety, reliability and convenient operation
4 PLC SIEMENS It has reliable and powerful performance.
5 Touch-screen Foinoe It achieves that the program parameters can be displayed and controlled
6 Program software Foinoe It adopts multiple programs with modularization management.
7 Mini printer Tianjin
Jingshi
It has long service life that clearly records relevant parameters.
8 Pressure sensor SMC High accuracy, good reliability, stable performance.
9 Flow sensor SMC High accuracy, good reliability.
10 Temperature
sensor
Zibo Feiyan Excellent stability with low error.
11 Sterile filter American
brand
It has high bacterial eliminating rate of 100%.
12 Magnetic valve SMC It adopts corrosion resisting material which has good reliability and long service life
13 Peristaltic pump British High accuracy, good reliability.
Detailed Photos

 

Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function OptionalFoinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function OptionalFoinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function OptionalFoinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function OptionalFoinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional
More pictures
Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional
Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional
Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional
Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional
 
Company Profile


Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional
FAQ
Foinoe Endoscope Washer-Disinfector with Leaking Test Function and Blocking Test Function Optional

About the Supplier

This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASR2541298". Items marked "verified" are certified.

Watch Video
Watch Video
Nanjing Foinoe Co., Ltd.
Nanjing Foinoe Co., Ltd.
Nanjing Foinoe Co., Ltd.
Nanjing Foinoe Co., Ltd.
Nanjing Foinoe Co., Ltd.
Nanjing Foinoe Co., Ltd.
Nanjing Foinoe Co., Ltd.
Nanjing Foinoe Co., Ltd.

About Our Factory & Business Background

verified Business Type
Trading Company
Address
15- 403, No. 52 Fengyousi Street, Qinhuai District, Nanjing, Jiangsu, China
verified Plant Area
289.37 square meters
verified Number of Employees
27
verified Registered Capital
6,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shanghai Port
verified Minimum Order Quantity
1 Set
verified Supply Chain Partners
340

Our Production Capability & Technical Expertise

verified Main Products
Medical Equipment, Dental Equipment, Electric Wheelchair, Hospital Equipment, Dental Cabinet, Operating Room Equipment
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
6 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2007-04-02
verified Export Year
18 Years
verified Main Markets
North America, Europe, East Asia(Japan/ South Korea)
verified Repeat Buyers Choice
80%~100%
verified Number of Foreign Trading Staff
14
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
Yes

Our Certifications, Standards & Industry Recognition

verified Cooperated with Fortune 500
No

FAQ

What models are available for the Foinoe Endoscope Washer-Disinfector?
The series includes Foinoe 50 (single-tank) and Foinoe 60 (double-tank). They are further divided into 50A/60A for one-off disinfectants and 50B/60B for reusable disinfectants.
How does the leaking test function work?
The leaking test finishes before the endoscope contacts liquid and continues during operation. It provides visual and audible signals and terminates operation if the leaking value exceeds the setting.
Is the blocking test function standard or optional?
The blocking test function is optional. It starts before and after the endoscope contacts liquid, terminating operation if a blockage is detected.
What types of disinfectants can be used?
It supports various disinfectants including glutaraldehyde, peracetic acid, OPA, chlorine dioxide, and electrolyzed oxidizing water.
What is the average lead time for orders?
The average lead time is within 15 workdays for both peak season and off-season periods.
What are the payment terms accepted?
Accepted payment terms include LC, T/T, D/P, PayPal, Western Union, and small-amount payment.
Can the machine be customized?
Yes, OEM and ODM services are available. Customization options include customization from samples, designs, full customization, minor customization, and flexible customization.
What is the minimum order quantity?
The minimum order quantity is 1 Set.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now