Product Description
Digital Mammography Medical X-ray Radiographic System FN-DM156A
Specifications
Configuration
No. |
Brand |
Model |
Product Name |
Quantity |
1 |
Foinoe |
TSM-1 |
DX Ray Diagnostic Workstation |
1 |
2 |
Kang Zhong |
CareView 750M |
X-ray Imaging System |
1 |
3 |
Foinoe |
FSQ-M-VMX1 |
High Frequency Generator |
1 |
4 |
Foinoe |
QG-M1 |
X-Ray Tube |
1 |
5 |
Foinoe |
XSM-2 |
Collimator |
1 |
6 |
Foinoe |
DM156-1 |
C-Arm Stand |
1 |
7 |
Foinoe |
YPQM-1/YPQM-2 |
Compression Device |
2 |
8 |
Foinoe |
YPQM-3 |
Compression Device (Optional) |
1 |
9 |
Linak |
FSE1200022/FSR0W00000/FSL0W00000 |
Foot Switch (A set of two) |
1 |
10 |
Steute |
MKF41PW-MEDGP47 |
Foot Switch (Optional) |
1 |
11 |
JPI |
JPI 2100 |
Grid (Optional) |
1 |
12 |
Foinoe |
/ |
High Voltage Cables |
2 |
13 |
|
/ |
Emergency Brake Switch |
1 |
14 |
|
/ |
Patient Handle |
1 |
15 |
|
/ |
Display |
2 |
16 |
|
/ |
Computer |
2 |
17 |
|
/ |
Report Laser Printer |
1 |
SYSTEM FEATURES
- User friendly design with auto-release breast compressor, it could release after each exposure, which will offer a comfortable experience for patients.
- 77μm detector could supply high quality image output with 4096x3072 resolution, and 24x30cm large view size, enable to assist best diagnosis even small nidus.
- One key positioning function and isocentric arm system can help radiographer make common position efficiently and safely.
- Mammography CAA Software, with GPU (Graphics Processing Unit) High Speed Image Processing Module, EAE high efficiency automatically intensifying Module, decrease image processing time, binging better image quality, help to find tiny lesions.
- Indicator to show the pressure, angle and thickness of breast, makes the examination visually and measurable.
AEC function enable to optimize the good image quality and dose management.
Digital Mammography FPD (CareView 750M)
- Application: General radiography
- Scintillator: CsI
- Pixel Size: 77μm
- Pixel matrix: 4096 x 3072
- Field of view: 24 x 30cm (10x12inch)
- Gradation: 16bits
- Resolution: 6lp/mm
- Communication: Gigabit-Ethernet
- Weight: 2.3kg
- Dimension: 33.3 x 26.8 x 1.5 cm
- AEC function available
DXRay Diagnostic Workstation (TSM-1)
Diagnostic workstation
- CPU: Inter Core i5
- OS: Windows 7 64bit
- Image Capture Memory: 8GB,Hard Drive: 500GBd
- Medical Monitor: 2M
- CD/DVD recording/burning
DXRayDiagnost software
Case management
- Case management function: including the management of patient information, exam information and images.
- Worklist enquiry service following standard DICOM3.0 may inquiry from HIS/PACS and download case information.
Image acquisition
- Acquisition system: positive and negative film image capture can be configured;
- Real time automatic window width level adjustment;
- Real time ROI (region of interests) clipping;
- Real time enhancement;
- Selecting image and rotation according to different body postures;
- Displaying patient information, examination information, device information and image information
Image processing
- Adjustment of window width, window level, Gamma, and LUT curve.
- Positive and negative film switchover, image zoom, translation, mirror image, rotation, magnified display;
- Image enhancement, noise reduction: Scheme and level of image enhancement and noise reduction can be adjusted according to different body postures.
- Image labeling function: including drawing straight line, rectangle, polygon, arrow and text;
- Real time reminding the free space of image disk of the system.
- RT prompt system can be used for store size of the disk space of image.
Image output
- Sending SCU with DICOM: support sending image to any PACS and workstations following Standard DICOM3.0;
Receiving SCP server with DICOM: support receiving image following Standard DICOM3.0 from any workstation.
5KW High Frequency Generator (FSQ-M-VMX1)
- Nominal supply voltage(50/60Hz): Single-phase 180-260VAC
- Power: 5 KW(31KV and 160mA)
- Output Voltage: 20-40KV
- Input Voltage: 220V
- Range of mAs: 10 - 120mAs /10-500mAs
- Range of mA: 10-200mA
Range of ms: 5ms-10000ms
X-Ray tube (QG-M1)
- Target Material: Molybdenum
- Focus: 0.1/0.3mm
- Angle of target: 15°
Anode Heat Capacity: 300kHU
Compression System and C Arm System (DM156-1)
- Compressor: Automatic Release Function and Manual Control Function\
- Size of compressor: 240x310mm, 100x100mm, 200x280mm
- Range of compressor: 280mm
- Pressure: 0-196N, shows on the indicator
- Distance from focus to the ground: 1420mm-2020mm,
- Arm Rotating Angle: -135°-+180°, shows on the indicator
- SID: 650mm
- Equipped with two rotating, lifting control switch
- Thickness detection, shows on the indicator
- One key positioning: +50°, 0°, -50°
- Dimension: 1900x1000x1135mm
- Grid: JPI 2100
- Ratio: 4:1
- Focus: 645mm
Line pairs: 332.5line/inch
Clinical Image
Company Profile
Customer Photo
Send your message to us and click "Send" now